Quality Policy
- Quality, Efficiency and Service
Environment Policy
- Strictly obey the legislations and regulations for pollution prevention.
- Continually improve the processes for saving the resources usage.
- Progressively manufacture the environment-protected products for the benefits of human society
Health and Safety Policy
- Strictly obey the legislations and regulations for the employee health and safety.
- Continually create the health and safety working environment.
- Progressively prevent the potential risk of endangering the health and safety.
Quality
- 100% visual inspection and electrical test
- Test data
- IPC
- Certification – ISO 9001
- XRF test data
- Solderability test
- Impedance modelling/testing
Items |
Descriptions |
1. IQC |
Incoming Quality Control for incoming raw material and Incoming Subcontract semi-products |
2. IPQC | In-process quality control, Every process online sampling inspection |
3. Chemical analysis | Chemical analysis to control online chemical solutionswithin control range |
4. Physical Laboratory | To do reliability tests and outgoing inspection items |
5. Micro-section | To analyze defects, every layer structure thickness, solder mask thickness, surface, and PTH copper thickness |
6. Black Light Inspection | To analyze the PTH hole copper coverage before Panel copper plating |
7. Lamination thickness measurement |
To control the product thickness quality even distribution and thickness tolerance under |
8. L/S measurement control by 3D |
To control the products after Pattern plating within the design spec. ( Line width and Space width) |
9. CMI measures copper thickness | CMI help to measure the PTH hole copper thickness and no need to damage the board by micro-section |
10. Impedance measurement |
For measuring Impedance control products ( Single strip, Differential …) |
11. Peel strength test |
Testing Solder Mask adhesive |
12. X-ray monitor multi-layer drilling | It controls inner and outer layer registration |
13. Hole AOI | To check hole location compare with Gerber design location accuracy |
14. XRF measures Nickel & Gold thickness | To measure surface finishing metal thickness |
15. Hi-Pot test | To checking the dielectric insulation capability |
16. 100% O/S test | To check circuit’s normal function as designedcircuit |
17. Hole counter | To check missing holes , hole size out thespec., no excess holes |
Reliability Test
Check Items |
Equipment |
Specification |
Frequency |
Purpose |
△ |
DSC(Eternal) |
△ Tg < 5℃ |
Once /month |
Assure the lamination condition is OK |
Surface insulation |
SIR &Chamber |
1.0X 1010Ω Min |
2 Pcs /month |
Assure the raw material condition is OK |
Solderability |
Solder Pot |
ANSI / STD-J-003 |
Once / Shipping Lot |
Assure the SMT wettability |
Thermal Stress |
Solder Pot |
IPC-6012B |
3Pcs / week | Assure the via-hole copper reliability |
S/M Abrasion Test |
6H Pencil |
IPC-SM-840D |
3Pcs / week | Assure the S/M curing is complete & quality |
Via HoleTHK & |
Microsection & |
IPC-6012B & |
Once / Shipping Lot | Assure the quality of the lamination and plating process |
Impedance |
Polar |
Customer Spec. |
Once / Shipping Lot |
Assure the quality of Impedance |
High Voltage |
Hi-Pot |
Customer Spec. |
Once / Shipping Lot |
Assure the quality of insulation |